Emission standards for coal mines
Pollutant Time wighted Avg. Concentration in Ambient Air Method of Measurement
New Coal Mines (Coal Mines coming up after Dec. 1998) Existing coal fields/mines given below:  Karanpura, Giridih, Rajhara, Wardha, Nagpur, Silewara, Pench, Kanhan, Patharkhera, Urmer, Korba, Chirimiri, Central India Coalfields (including Baikunthpur, Bisrampur), Singrauli, Ib Valley, Tacher, and Godavary- Vally coalfields Old Coal Mines -Jharia -Raniganj  -Bokaro
Suspended Particulate Matter (SPM) Annual   Average*     360 mg/m3 430 mg/m3 500 mg/m3   High Volume Satmpling (Average flow rate not less than 1.1m3/minute)
24 hours** 500 mg/m3 600 mg/m3 700 mg/m3
Respirable Particulate Matter (size less than 10 mm) (RPM) Annual  Average*           180 mg/m3 215 mg/m3 250 mg/m3 Respirable Particulate Matter Sampler
24 hours** 250 mg/m3 300 mg/m3 300 mg/m3
Sulphur Dioxide (SO2) Annual  Average*     80 mg/m3 80 mg/m3 80 mg/m3  Improved west and Gaeke Method
24 hours** 120 mg/m3 120 mg/m3 120 mg/m3 Utraviolet fluorescene
Oxide of Nitrogen as NO2 Annual Average*           80 mg/m3 80 mg/m3 80 mg/m3 Jacob & Hochheiser Modified (Na-Aresnic) Method
24 hours** 120 mg/m3 120 mg/m3 120 mg/m3 Gas phase Chemilumine-scence
Note  : *   : Annual Arithmatic mean for the measurements taken in a Year, following  guidelines for frequency of sampling.
            : ** : 24 hourly / 8 hourly values should met 98% of the time in a year. However 2% of the time it may exceed but not no two consecutive days.
 1 - The ambient air quality standards shall apply to the nearest residential  / commercial places (existing / lilely) on the leaward direction on the mining and allied activities.
 2 - Unauthorised construction will not be taken as a reference of nearest   residential / commercial place for monitoring.
Source : Environmental Standards for Ambient Air, Automobiles, Fuels, Industries   and Noise, Central Pollution Control Board, Ministry of Environment & Forest.