| Stack Height/Limits of Kiln unit | |
| Kiln Capacity | Recommended Stack Height for Optimum Dispersion of Sulphur Dioxide |
| Less than 15,000 bricks are day (less than 15 ft trench width) | Minimum stack height of 22 m, or, incluced draught fan operating with minimum draught of 50 mm Water Gauge With 12 m stack height. |
| 15,000-30,000 bricks per day (more Than 15-22 ft trench width) | Minimum stack height of 27 m with gravitational settling chamber |
| or | |
| Induced draught fan operating with minimum draught of 50 mm Water Gauge With 15 m stack height. | |
| More than 30,000 bricks per day (More than 22 ft trench width) | Minimum stack height of 30 m with gravitational setting chamber |
| or | |
| Induced draught fan operating with minimum draught of 50 mm water gauge with 17 m stack height. | |